1. Application
This product is suitable for fixed power transmission lines of rated voltage (Uo/U) 0.6/1kV and below where high working temperature is available.

2. Code and Description

Code Description Working Temperature
FF-20 F46 insulated & sheathed power cable -60℃ -200℃
FF22-200 F46 insulated steel tape arrmored F46 sheathed power cable -60℃ -200℃
FV105 F46 insulated 105℃ PVC sheathed power cable -15℃ -105℃
FV22-105 F 46 insulated steel tape armored 105℃ PVC sheathed power cable -15℃ -105℃

4. Models Available
Code No. of Cores Sectional Area (mm2)
FF-200 1, 2, 3, 4, 3+1 1.5-240
FV-105 1, 2, 3, 4, 3+1 1.5-185
FF22-200 2, 3, 4, 3+1 4-185
FV22-105 2, 3, 4, 3+1 4-185

The neutral core sectional area of 3+1 core cable shall be as specified in the following table
Phase Core Neutral Core Phase Core Neutral Core Phase Core Neutral Core
4 2.5 25 16 95 50
6 4 35 16 120 70
10 6 50 25 150 70
16 10 70 35 185 95

5. Guide to Use
1) Rated voltage Uo/U: 0.6/1kv
2) The max. conductor temperature in normal use:
FF-200, FF22-200: 200
FV-105, FV22-105: 105
3) Ambient temperature during installation:
FF-200, FF22-200: -60 ~ 200
FV-105, FV22-105: -15 ~ 105
4) The min. bend radius is 15 times cable radius
5) The product has excellent anti-corrosion, weather-proof, flame-retardant and water-proof performances.
6) Resistance of the conductor meet requirements of GB 3956.
7) The cable shall withstand a 3.5kv/5min voltage test and no breakdown shall occur.

Other Products

  • Screened Multi-pair Computer (including DCS System) Cable

  • Compensation cable

  • Heat-resistant Fire-proof Cable

  • Silicone Rubber Insulated Power Cable

  • Silicone Rubber Insulated Control Cable

  • Heat-Resistant Flat Cable

  • Teflon Insulated Heat-resistant Control Cable

  • High temperature control cable

  • Heat-Resistant & Cold-Resistant Flat Cable