PRODUCTS
- Distribution Transformer
- Resin Casting Dry Type Power Transformer
- Whole-sealed Type Distribution Power Transformer
- Electrical Power Fitting
- Power Transmission and Distribution Fittings
- Power Line Fittings
- Power Line Helical Fittings
- High Voltage Outdoor Electrical Equipment
- Copper and Aluminum Contact Arms
- Lightening Protection Grounding Clamps
- Electric Wire & Cable and Accessories
- Rubber Sheathed Cable for General Purposes
- Rubber Insulated Cables Used in Open Countr
- Flame-retardant Rubber Sheathed Cables for Mining Purposes
- PVC Insulated Cable for House Wiring
- XLPE Insulated Power Cable
- PVC Insulated Power Cable
- Low-smoke Halogen-free Flame-retardant and Fire-resistant Cables
- Control Cables
- Overhead Conductors and Cables
- Aluminum wire and ACSR
- Special Cables
- Elevator Cable
HOTLINE
0577-57157777
Special Cables
Heat-resistant Fire-proof Cable
- Share:
1. Application
This product is used in signal and power transmission lines of rated voltage 0.6/1kV and below where high working temperature is need. It is especially used in fire control and protection systems.
Code | Description |
NHFF | Copper core fire-proof & insulation layer heat-resistant fire-proof cable |
NHFF22 | Copper core fire-proof & insulation layer steel tape armored heat-resistant fire-proof cable |
NHFF32 | Copper core fire-proof & insulation layer steel-wire armored heat-resistant & fire-proof cable |
NHFP1F | Copper core fire-proof & insulation layer heat-resistant shield fire-proof cable |
NHFP1F22 | Copper core fire-proof & insulation layer steel tape armored heat-resistant shield fire-proof cable |
NHFP1F32 | Copper core fire-proof & insulation layer steel wired armored heat-resistant shield fire-proof cable |
3. Technical Performance
Item | Unit | Technical Parameter | |||||||||||||||
Max. Conductor DC Resistance at 20℃ | Ω/km | Sectional area (mm2) | 0.5 | 0.75 | 1.0 | 1.5 | 2.5 | 4 | 6 | 10 | 16 | 25 | 35 | 50 | 70 | 95 | 120 |
Resistance | 36.0 | 24.5 | 18.1 | 12.1 | 7.41 | 4.6 | 3.08 | 1.83 | 1.15 | 0.727 | 0.524 | 0.387 | 0.268 | 0.193 | 0.153 | ||
Test Voltage | kV/1min |
450/750V Cable: Test Voltage 2.5kV 600/1000V Cable: Test Voltage 3.5kV |
|||||||||||||||
Insulation Resistance | MΩ.km | 100 | |||||||||||||||
Fire-resistant Performance |
|
Grade A (in 1000℃ flame for 90 minutes, 3A fuse does not break) |
4. Guide to Use
1) Working temperature: 200℃ in normal use and 1000℃ for short-term use.
2) Rated votage Uo/U: 450/750V, 600/1000V.
3) Min. ambient temp: -60℃ for fixed installation and -20℃ for portable application.
4) Min. bend radius: 10 times cable diameter for non-armored cable and 12 times cable diameter for armored cable.
5. Models Available
Model | Nominal Sectional Area (mm2) | ||||||||||||||
0.5 | 0.75 | 1.0 | 1.5 | 2.5 | 4 | 6 | 10 | 16 | 25 | 35 | 50 | 70 | 95 | 120 | |
No. of Cores | |||||||||||||||
NHFF | 2-61 | 2-10 | 1-5 | ||||||||||||
NHF22 | - | 4-61 | 2-10 | 2-5 | |||||||||||
NHFF32 | - | 4-61 | 4-10 | 3-5 | |||||||||||
NHFP1F | 2-61 | 2-10 | 1-5 | ||||||||||||
NHFP1F22 | - | 4-61 | 2-10 | 2-5 | |||||||||||
NHFP1F32 | - | 4-61 | 4-10 | 2-5 |
-
Screened Multi-pair Computer (including DCS System) Cable
-
Compensation cable
-
Silicone Rubber Insulated Power Cable
-
Silicone Rubber Insulated Control Cable
-
Heat-Resistant Flat Cable
-
Teflon lnsulated Power Cable
-
Teflon Insulated Heat-resistant Control Cable
-
High temperature control cable
-
Heat-Resistant & Cold-Resistant Flat Cable